B.1
Technical Specifications of the SIMATIC Box PC 620
General
Order nos.
Order nos.
See order documentation
Dimensions (w x h x d)
295x265x80 mm, without CD-ROM drive
295x265x100 mm, with CD-ROM drive
Weight
approx. 6kg (13.5 lbs.)
Supply voltage (U
N
)
120 V (85 V to 132 V (AC),
or 230 V (170 V to 265 V) AC (autorange)
alternative: 24 V (20.4 bis 28.8 V) DC, SELV
alternative: 24 V (20.4 bis 28.8 V) DC, SELV
Line voltage frequency, AC
50/60 Hz (47 to 63 Hz)
Brief voltage interruption acc. to Namur
max. 20 ms at 0.85 U
N
(max. 10 times per hour; min. recovery time 1 s)
max. power consumption for 85W power supply 120W
max. power consumption for 105W power
max. power consumption for 105W power
supply
132W
max. current output (DC), according to form of
power supply
+5V/ 10A or 13.5A
3,3V/4.2A or 8.5A
+12V/1.7 A or 2.5A
–12/0.2A or 0.3A (in total max. 85W or 105W)
3,3V/4.2A or 8.5A
+12V/1.7 A or 2.5A
–12/0.2A or 0.3A (in total max. 85W or 105W)
Noise emission
< 55dB(A) to DIN 45635
Enclosure
IP20
Safety
Protection class
Protection class
Protection class I pursuant IEC 60536
Safety specifications with AC power supply
UL1950/IEC 60950 corresponds to DIN VDE 0805
Safety specifications with DC power supply
UL508
Electromagnetic compatibility (EMC)
Emitted interference with power supply 105W
Emitted interference with power supply 105W
EN 55022 Class A (requirement for industrial sector)
for devices with AC power supply EN6100-3-2 class D
and EN61000-3-3
Emitted interference with power supply 85W
EN 55022 Class B (requirement for domestic and
industrial sector)
for devices with AC power supply EN6100-3-2 class D
and EN61000-3-3
Noise immunity:
Mains borne disturbance variables on supply
Mains borne disturbance variables on supply
lines
±.2 kV
(to IEC 61000-4-4; Burst)
± 1 kV
(to IEC 61000-4-5; Surge symm)
± 2 kV
(to IEC 61000-4-5; Surge unsymm)
Noise immunity on signal lines
± 1 kV
(IEC 61000-4-4; Burst; length < 5 m)
± 2 kV
(IEC 61000-4-4; Burst; length > 5 m)
± 2 kV
(to IEC 61000-4-4:1995; Surge unsymm;
length > 30 m)
Noise immunity to discharges of static electricity ± 6 kV Contact discharge
(to IEC 61000-4-2)
± 8 kV Air discharge
(to IEC 61000-4-2)
Immunity to RF interference
10 V/m 80-1000 MHz, 80% AM (to IEC 61000-4-3)
10 V/m 900 MHz and 1,89 GHz, 50% ED
10 V/m 900 MHz and 1,89 GHz, 50% ED
(to IEC 61000-4-3)
10 V 9KHz- 80MHz
10 V 9KHz- 80MHz
(to IEC 61000-4-6)
Magnetic field
30 A/m 50Hz