Toshiba S4 Benutzerhandbuch

Seite von 470
Appendices 
Appendix J  Maintenance of TOSHIBA RAID
J-2
[CONFIDENTIAL]]
TECRA S3 Maintenance Manual (960-532)
J.2
Analysis and handling by Drive Log
Follow the below procedures to analyze.
Figure J-2  Flowchart of Analysis and handling by Drive Log
Boot the independent utility
and check the Physical Drive
status.
(2) If necessary, analyze the
Drive Log and identify
the cause of failure.
Yes
(3) Does operation
miss cause it?
Replace the built-in HDD with
the second HDD removed.
Replace the second HDD
with new (good) one.
(4) Change the status of the
failed HDD to “OFFLINE”.
Port 0
(1) Which port of
HDD failed?
(2) If necessary, analyze the
Drive Log and identify
the cause of failure.
Port 1
No
Replace the second HDD
with new (good) one.
End