Toshiba satellite a20 series Benutzerhandbuch

Seite von 495
3.23  Running Test 
3   Tests and Diagnostics 
3.23 Running Test 
3.23.1 Function 
Description 
This function automatically executes the following tests in sequence: 
1.  System test (subtest 01) 
2.  Memory test (subtests 01, 02, 04, and 06) 
3.  Real timer test (subtest 02) 
4.  Display test (subtest 01) 
5.  FDD test (subtest 02) 
6.  HDD test (subtests 01 and 05) 
7.  Printer test (subtest 03) if selected 
8.  Async test (subtest 01) (not supported in this model) 
3.23.2 Operations 
NOTE: Do not forget to load a work disk in the FDD. If a work disk is not loaded, an error 
will be generated during the FDD testing. 
1.  Remove the diagnostics disk from the floppy disk drive and insert the work disk. 
2. Select 
6
 from the Diagnostic Menu and press 
Enter
, the following message displays: 
Printer wrap around test (Y/N) ? 
Selecting 
Y (yes)
 executes the printer wraparound test. A printer wraparound connector 
must be connected to the parallel port of the computer to properly execute this test. 
3. Select 
Y 
or 
N
 and press 
Enter
. The following message will appear: 
Serial#A wrap around test (Y/N) ? 
Selecting 
Y (yes)
 executes the ASYNC wraparound test. An RS-232-C wraparound 
connector must be connected to the serial port of the computer to properly execute this 
test.  
Satellite A20 Maintenance Manual (960-444) 
 
3-59