2.2  Basic Flowchat 
2  Troubleshooting 
TECRA S1  Maintenance Manual 
2-5 
If the diagnostic program cannot detect an error, the error may be intermittent.  Run the 
continuous test program repeatedly to isolate the problem.  Check the log utilities function to 
confirm which diagnostic test detected the error, then perform the appropriate 
troubleshooting procedures as follows: 
 
1.  If an error is detected by the System test, Memory test, Async test, Printer test,  
Sound test, or Real Timer test, follow the system board troubleshooting procedures in 
Section 2.4. 
2.  If an error is detected by the Hard Disk test, follow the HDD troubleshooting 
procedures in Section 2.6. 
3.  If an error is detected by the Keyboard test, follow the keyboard troubleshooting 
procedures in Section 2.6. 
4.  If an error is detected by the Display test, follow the display troubleshooting 
procedures in Section 2.8. 
5.  If an error is detected by the DVD-ROM test, follow the DVD-ROM troubleshooting 
procedures in Section 2.9. 
6.  If an error is detected by the CD-ROM test, follow the CD-ROM troubleshooting 
procedures in Section 2.10. 
7.  If an error is detected by the LAN test, follow the LAN troubleshooting procedures in 
section 2.12. 
8.  If an error is detected by the Fan On/Off test, follow the cooling module 
troubleshooting procedures in Section 2.13.