Specifications
Dimensions (WxHxD)
20" x 20" x 8"
(50.8 cm x 50.8 cm x 20.32)
Weight
48 lbs. (21 kg)
Operating Environment
32 – 104˚F (0-40˚C)
Monitored Parameters:
• Input Voltage (L-L)
• Output Voltage (L-L, L-N)
• Output Current
• Output Neutral
• Ground Current
• Output Frequency
• Output kVA
• Output Kilowatts
• Output Power Factor
• Output Percent Load
Alarms:
• Output Overvoltage
• Frequency Deviation
• Phase Sequence Error
• Phase Loss
• Output Undervoltage
• Output Overcurrent
• Neutral Overcurrent
• Ground Overcurrent
• Up To Four Normally Open Contact Closures
• One Normally Closed Contact Closure
• One Normally Open Form C Summary 
Alarm Contact
• One Normally Closed Form C Summary 
Alarm Contact
True Rms Monitoring.
Accurate representation of non-sinusoidal
waveforms typical of computers and other
sensitive loads.
Emergency Power Off.
When selected, the lighted, covered switch, 
will immediately power down the connected
equipment by activating a shunt trip of the main
input breaker (if the system is equipped with
shunt trip capabilities).
L
I E B E R T
C
O R P O R A T I O N
1050 D
EARBORN
D
RIVE
P.O. B
OX
29186
C
OLUMBUS
, O
HIO
43229
800.877.9222 P
HONE
(U.S. & 
C
ANADA
O
NLY
)
614.888.0246 P
HONE
(O
UTSIDE
U.S.)
614.841.6022 FAX
V
IA
L
EONARDO
D
A
V
INCI
8
Z
ONA
I
NDUSTRIALE
T
OGNANA
35028 P
IOVE
D
I
S
ACCO
(PD)
I
TALY
39 049 9719 111 P
HONE
39 049 5841 257 FAX
23/F A
LLIED
K
AJIMA
B
LDG
.
138 G
LOUCESTER
R
OAD
W
ANCHAI
H
ONG
K
ONG
852 2 572 2201 P
HONE
852 2 831 0114 FAX
L
I E B E R T
W
E B
S
I T E
http://www.liebert.com
2 4  
X
7   T
E C H
S
U P P O R T
800 222 5877 P
HONE
614 841 6755 (
OUTSIDE
U.S.)
While every precaution has been taken to ensure accuracy and 
completeness in this literature, Liebert Corporation assumes no
responsibility, and disclaims all liability for damages resulting 
from use of this information or for any errors or omissions.
© 2002 Liebert Corporation. All rights reserved throughout 
the world. Specifications subject to change without notice. 
All names referred to are trademarks or registered trademarks 
of their respective owners.
® Liebert and the Liebert logo are registered trademarks 
of the Liebert Corporation.
® Keeping Business in Business is a registered trademark 
of the Liebert Corporation.
The Emerson logo is a trademark and service mark 
of Emerson Electric Co.
SL-31040 (R5/02)
Printed in USA
Adjustable Alarm Threshold.
Adjusted using the RS-232-C service port.
Adjustable parameters include: Output
overvoltage, undervoltage, and overcurrent;
Neutral overcurrent; Ground overcurrent; 
and Frequency deviation.
Field Programmable Custom Alarms.
Up to four normally open and one normally
closed custom alarms are available. A custom
alarm message of up to 20 characters is
available for each alarm, programmable 
through the RS-232-C port.
Summary Alarms.
Form C summary alarm contact (one normally
open, one normally closed) are provided.
Battery-Backed Alarms.
Alarm parameters are battery backed to prevent
loss in case of a power outage.
Eia-422-A Communication Port.
Reliable communication up to 1000 meters.
Eia-232-C Service Port.
Allows for parameter adjustment.
Local And Centralized Monitoring.
Monitored parameters and alarms are displayed
locally on the RPMP monitor panel. The RPMP
can also communicate with the Liebert SiteScan
Centralized Monitoring system, providing
convenient monitoring and control for all your
critical application needs.
The unit front monitoring panel 
displays up to 4 lines of text, with up 
to 20 characters per line. The large
viewing area allows easy monitoring 
of complete information.
R e m o t e   P o w e r   M o n i t o r   P a n e l   ( R P M P )