Best use of Battery Power 
Make sure any appliances are energy efficient and turned off after use. 
Use Compact Florescent Lamps. Wherever possible, charge with Solar 
Panels or Wind Generators. Do not allow lead acid batteries to remain 
discharged for long periods of time, they lose capacity (amp hours).  
  
Disposal / Recycling of Inverter / California Proposition 65 
Electronic products are known to contain materials that are toxic if 
improperly disposed. Contact local authorities for disposal and recycling 
information. 
 
This inverter is certified to be “lead free.” Transformers in this inverter 
contain nickel composites. Nickel is a known neuro-toxin if ingested.   
 
Troubleshooting 
 
     PROBLEM: No Input Voltage 
Reason 
Solution 
Poor contact with battery 
terminals. 
Shut down inverter and 
disconnect. Clean terminals 
thoroughly and reconnect.  
Blown DC battery fuse(s). 
Turn off inverter. Fix problem. 
Replace fuse(s) with same type 
and rating. 
 
PROBLEM: Inverter is Shut Down 
Reason 
Solution 
Battery voltage below 10 
Volts. 
Charge or replace battery. 
Inverter is too hot (thermal 
shut down mode). Will be 
indicated on LCD panel. 
Allow inverter to cool. Check 
for adequate ventilation. Re-
duce the load on the inverter 
to rated continuous power. 
Unit may be defective. 
See warranty and call 
customer service.