Fuji Bikes 5000G11S/P11S Benutzerhandbuch

Seite von 132
 
 
9-3
9-2 Common Specifications 
Item Explanation 
Control method 
Sinusoidal wave PWM control (with V/F control, torque vector control, PG feedback vector control (option)) 
Maximum 
frequency 
G11S:    50 to 400Hz variable setting    P11S:    50-120Hz variable setting 
Base 
frequency 
G11S:    25 to 400Hz variable setting    P11S:    25-120Hz variable setting 
Starting 
frequency 
0.1 to 60Hz variable setting    Holding time:    0.0 to 10.0 s 
Carrier 
frequency 
G11:    0.75 to 15kHz (75HP or less)    0.75 to 10kHz (100HP or more) 
P11:    0.75 to 15kHz (30HP or less)    0.75 to 10kHz (40 to 100HP) 0.75 to 6kHz (125HP or more) 
Accuracy 
(stability) 
Analog setting:    +/- 0.2% or less of the max. Frequency (at 25℃ (77
°F) +/- 10℃ (50°F)) 
Digital setting:    +/- 0.01% or less of the max. Frequency (-10℃ (14
°F) to +5℃ (122°F)) 
Ou
tp
u
t fr
eq
ue
nc
Setting 
resolution 
Analog setting:    1/1000 of max. frequency (30HP or less)    1/3000 of max.    frequency (40HP or more) 
Digital setting:    0.01Hz (99.99Hz or less), 0.1Hz (100.0Hz or more) 
Voltage/frequency 
characteristics 
Output voltage at base frequency can be adjusted separately, such as 80 to 240V (230V series) or 320 to 480V 
(460V series). 
Output voltage at max. frequency can be adjusted separately, such as 80 to 240V (230V series) or 320 to 480V 
(460V series). 
Torque boost 
Auto:    Optimum control corresponding to the load torque. 
Manual:    0.1 to 20.0 code setting (energy saving reduced torque, constant torque (strong), etc.) 
Accelerating/decelerating 
time 
0.01 to 3600s 
Four accelerating and decelerating time settings are possible independent of each other by selecting digital input 
signals. 
In addition to linear acceleration and deceleration, either S-shaped acceleration/deceleration (weak/strong) or 
curvilinear acceleration/deceleration can be selected. 
DC injection braking 
Starting frequency:    0.0 to 60.0Hz, braking time:    0.0 to 30.0s, 
Braking level:    0 to 100% (G11S), 0-80% (P11S) 
Co
n
tro
Function equipped 
Frequency upper and lower limiter, bias frequency, frequency gain, jump frequency, pick-up operation, restart 
after momentary power failure, switching operation from line to inverter, slip compensation control, automatic 
energy saving operation, regeneration avoiding control, droop control, torque limiting (2-step), torque control, PID 
control, second motor switching, cooling fan ON/OFF control. 
Operation method 
Keypad panel:  Run by       ,       keys, stop by        key 
Terminal input:  Forward/stop command, reverse/stop command, coast-to-stop command, alarm reset, 
acceleration/deceleration selection, multistep frequency selection, etc. 
Frequency setting 
 
Keypad panel:  Setting by       ,       keys 
External potentiometer:    External freq.setting POT (VR) (1 to 5kΩ) 
Analog input:    0 to +10V (0 to +5V), 4 to 20mA, 0 to +/- 10V (FWD/REV operation) 
+10 V to 0 (reverse operation), 20 to 4mA (reverse operation) 
UP/DOWN control:    Frequency increases or decreases as long as the digital input signal is turned on. 
Multistep frequency selection:    Up to 15 steps are selectable by a combination of digital input signals (four kinds).
Link operation:    Operation by RS-485 (standard). 
Program operation:    Pattern operation by program 
Jogging operation:  Jogging operation by       ,      key or digital input signals 
O
per
ati
on 
Operation status signal 
Transistor output (4 signals): Running, frequency arrival, frequency detection, overload early warning, etc. 
Relay output (2 signals): Alarm output (for any fault), multi-purpose relay output signals 
Analog output (1 signal): Output frequency, output current, output voltage, output torque, power consumption, etc.
Pulse output (1 signal): Output frequency, output current, output power, output torque, power consumption, etc. 
Digital display (LED) 
Output frequency, setting frequency, output current, output voltage, motor synchronous speed, line speed, load 
rotation speed, calculated torque value, power consumption, calculated PID value, PID command value, PID 
feedback value, alarm code 
Liquid crystal display (LCD) 
Operation information, operational guide, functional code/name/setting data, alarm information, tester function, 
motor load rate measuring function (Maximum/average current (rms) during measuring period, maintenance 
information (Integrated operation hours, capacitance measurement for main circuit capacitors, heat sink 
temperature, etc.)) 
Language 
Six languages (Japanese, English, German, French, Spanish, and Italian) 
Ind
ic
a
tion 
Lamp display 
Charging (voltage residual), operation indication 
Protective functions 
Overcurrent, short-circuit, ground fault, overvoltage, undervoltage, overload, overheating, blown fuse, motor 
overload, external alarm, input open-phase, output open-phase (when tuning), braking resistor protection, CPU 
and memory error, keypad panel communication error, PTC thermistor protection, surge protection, stall 
prevention, etc. 
Installation location 
Indoor, altitude less than 3300ft (1000m), free from corrosive gas, dust, and direct sunlight (Pollution degree 2) 
Ambient temperature 
-10℃ (14
°F) to +50℃ (122°F)  (ventilating cover must be removed under conditions exceeding +40℃ (104°F) 
for models rated at 30HP or less) 
Ambient humidity 
5 to 95%RH (no condensation) 
Air pressure 
Operation/storage :86 to 106 kPa 
Transport        :70 to 106 kPa 
Vibration 
0.12inch(3mm) at from 2 to less than 9Hz, 9.8m/s
2
 at from 9 to less than 20Hz, 
2m/s
2
 at from 20 to less than 55Hz, 1m/s
2
 at from 55 to less than 200Hz, 
Ambient 
temperature 
-25℃ (-13
°F) to +65℃ (149°F) 
E
n
vir
onm
ent 
Storage 
Ambient humidity 
5 to 95%RH (no condensation) 
FWD
FWD
REV
REV
STOP