Intel EPS1U Benutzerhandbuch

Seite von 31
 
SSI
  
EPS1U Power Supply Design Guide, V1.1 
5.4  Efficiency 
 
STATUS 
Required 
The power supply shall have a minimum efficiency of 68% at maximum load and over the specified AC voltage.  
There is no efficiency requirement for the 125W version. 
5.5  AC Line Dropout 
 
STATUS 
Required 
An AC line dropout is defined to be when the AC input drops to 0 VAC at any phase of the AC line for any length 
of time.  During an AC dropout of one cycle or less the power supply must meet dynamic voltage regulation 
requirements over the rated load.  An AC line dropout of one cycle or less shall not cause any tripping of control 
signals or protection circuits.  If the AC dropout lasts longer than one cycle, the power supply should recover and 
meet all turn on requirements.  The power supply must meet the AC dropout requirement over rated AC voltages, 
frequencies, and output loading conditions.  Any dropout of the AC line shall not cause damage to the power 
supply. 
5.6  AC Line Fuse 
 
STATUS 
Required 
The power supply shall incorporate one input fuse on the LINE side for input over current protection to prevent 
damage to the power supply and meet product safety requirements.  Fuses should be slow blow type or 
equivalent to prevent nuisance trips. AC inrush current shall not cause the AC line fuse to blow under any 
conditions.  All protection circuits in the power supply shall not cause the AC fuse to blow unless a component in 
the power supply has failed.  This includes DC output load short conditions. 
 
STATUS 
Optional 
Some system applications may require a second input fuse in the NEUTRAL side of the AC input.  In this case 
two fuses would be required; one in the LINE side and one in the NEUTRAL side of the AC inlet to the power 
supply. 
5.7  AC Inrush 
 
STATUS 
Required 
The power supply must meet inrush requirements for any rated AC voltage, during turn on at any phase of AC 
voltage, during a single cycle AC dropout condition, during repetitive ON/OFF cycling of AC, and over the 
specified temperature range (T
op
).  The peak inrush current shall be less than the ratings of its critical components 
(including input fuse, bulk rectifiers, and surge limiting device).