Intel EPS1U Benutzerhandbuch

Seite von 31
 
SSI
  
EPS1U Power Supply Design Guide, V1.1 
8.5  LED Indicator 
 
STATUS 
Required 
There will be a single GREEN LED to indicate power supply status.  When AC is applied to the PSU and standby 
voltages are available the LED shall BLINK GREEN.  The LED shall turn ON GREEN to indicate that all the power 
outputs are available.  Refer to Table 26 for conditions of the LED. 
Table 26:  LED Indicators 
Power Supply Condition 
Power Supply LED 
No AC power to PSU or PSU failure 
OFF 
AC present / Only Standby Output ON 
BLINK GREEN 
Power supply DC outputs ON and OK 
GREEN 
The LED shall be visible on the power supply’s exterior face. The LED location shall meet ESD requirements. 
LED shall be securely mounted in such a way that incidental pressure on the LED shall not cause it to become 
displaced. 
MTBF 
 
STATUS 
Recommended 
The power supply shall have a minimum MTBF at continuous operation of 1) 100,000 hours at 100% load and 
45
° 
C, as calculated by Bellcore RPP, or 2) 250,000 hours demonstrated at 100% load and 45
° 
C.