Specification 
OUTPUT 
Voltage Range: 
0V to 18V minimum 
Current Range: 
0A to 10A minimum 
Output Voltage Setting: 
By coarse and fine controls. 
Output Current Setting: 
By single logarithmic control. 
Operating Mode: 
Constant voltage or constant current with automatic cross-over. 
Output Switch: 
Electronic. Preset voltage and current displayed when off. 
Output Terminals: 
4mm terminals on 19mm (0.75”) pitch. 
Output Impedance: 
Typically <5m
Ω in constant voltage mode.  
Typically >10k
Ω in constant current mode. 
Output Protection: 
Output will withstand up to 22V forward voltage.  
Reverse protection by diode clamp for reverse currents up to 3A. 
Load & Line Regulation: 
<0.01% of maximum output for a 90% load change or 10% line 
change. 
Ripple & Noise 
(20MHz bandwidth): 
Typically <2mVrms, <10mV pk-pk, constant voltage mode. 
Transient Response: 
<200µs to within 50mV of set level for 90% load change. 
Temperature Coefficient: 
Typically <100ppm/°C 
Status Indication: 
Output on lamp.  Constant current mode lamp. 
METER SPECIFICATIONS 
Meter Types: 
Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz. 
Meter Resolutions: 
10mV, 10mA 
Meter Accuracies: 
Voltage 0.3% of reading ± 2 digits  
Current 0.6% of reading ± 2 digits 
GENERAL 
AC Input: 
Factory set for: 110V - 120V AC ±10% or 220V - 240V AC ±10%,  
50/60Hz. Installation Category II. 
Power Consumption: 
400VA max. 
Operating Range: 
+5ºC to +40ºC, 20% to 80% RH. 
Storage Range: 
−40ºC to + 70ºC. 
Environmental: 
Indoor use at altitudes up to 2000m, Pollution Degree 2. 
Safety: 
Complies with EN61010
−1. 
EMC: 
Complies with EN61326. 
Size: 
140 x 160 x 320mm (WxHxD). 
Weight: 2.8kg