Xantrex Technology 18V 10A Benutzerhandbuch
Specification
OUTPUT
Voltage Range:
0V to 18V minimum
Current Range:
0A to 10A minimum
Output Voltage Setting:
By coarse and fine controls.
Output Current Setting:
By single logarithmic control.
Operating Mode:
Constant voltage or constant current with automatic cross-over.
Output Switch:
Electronic. Preset voltage and current displayed when off.
Output Terminals:
4mm terminals on 19mm (0.75”) pitch.
Output Impedance:
Typically <5m
Ω in constant voltage mode.
Typically >10k
Ω in constant current mode.
Output Protection:
Output will withstand up to 22V forward voltage.
Reverse protection by diode clamp for reverse currents up to 3A.
Reverse protection by diode clamp for reverse currents up to 3A.
Load & Line Regulation:
<0.01% of maximum output for a 90% load change or 10% line
change.
change.
Ripple & Noise
(20MHz bandwidth):
(20MHz bandwidth):
Typically <2mVrms, <10mV pk-pk, constant voltage mode.
Transient Response:
<200µs to within 50mV of set level for 90% load change.
Temperature Coefficient:
Typically <100ppm/°C
Status Indication:
Output on lamp. Constant current mode lamp.
METER SPECIFICATIONS
Meter Types:
Dual 4 digit meters with 14mm (0.56") LEDs. Reading rate 4 Hz.
Meter Resolutions:
10mV, 10mA
Meter Accuracies:
Voltage 0.3% of reading ± 2 digits
Current 0.6% of reading ± 2 digits
Current 0.6% of reading ± 2 digits
GENERAL
AC Input:
Factory set for: 110V - 120V AC ±10% or 220V - 240V AC ±10%,
50/60Hz. Installation Category II.
50/60Hz. Installation Category II.
Power Consumption:
400VA max.
Operating Range:
+5ºC to +40ºC, 20% to 80% RH.
Storage Range:
−40ºC to + 70ºC.
Environmental:
Indoor use at altitudes up to 2000m, Pollution Degree 2.
Safety:
Complies with EN61010
−1.
EMC:
Complies with EN61326.
Size:
140 x 160 x 320mm (WxHxD).
Weight: 2.8kg
3