Chapter 10 Wiring the modules 135
Installation and Maintenance Guide
Connecting media bay modules to Service Providers
To connect DTM, CTM, CTM8, 4X16, or BRI media bay modules to the network, follow these
steps:
steps:
1
On the front of the module, locate the RJ48C socket (DTM), RJ45 sockets (BRI), or the
RJ11 sockets (CTM and 4X16 modules).
RJ11 sockets (CTM and 4X16 modules).
2
Wire one end of the cable to the telco demarcation blocks of the building.
•
shows the wiring pinouts for a DTM to connect to a service provider.
Figure 53 DTM RJ48C wiring array
•
shows the wiring pinout for a CTM, a CTM8, or the CTM jacks on a 4X16
module, to connect to the service provider.
All the modules have an auxiliary jack (the CTM8 has two). Do not attempt to plug digital
equipment into this jack.
equipment into this jack.
Figure 54 CTM RJ11 wiring array
Warning:
If you are using a service provider bus service unit (CSU), you must disable the
Business Communications Manager system internal CSU using Business Communications
Manager Unified Manager. For more information, refer to the Business Communications
Manager Programming Operations Guide.
Manager Unified Manager. For more information, refer to the Business Communications
Manager Programming Operations Guide.
1 2 3 4 5 6 7 8
DTM connector
To network
To plug
Receive from
network
network
1- Rring
2 - Rtip
3 - Rshield
Transmit to network
4-Tring
5-Ttip
6-Tshield
RJ48C jack
6 5 4 3 2 1
CTM
connector
connector
RJ11 sockets
Auxiliary jack
Pin #/connection
3- Ring
4 - Tip
The CTM 8 has eight RJ11 jacks, including two
auxiliary jacks.
auxiliary jacks.
The 4X16 media bay module has four RJ11 jacks.