Installation and Maintenance Guide
Chapter 12
Installing Analog Terminal Adapters
This chapter provides installation instructions for the Analog Terminal Adapter 2 (ATA 2).
The ATA 2 connects a standard analog voice device or data communication device to the Business 
Communications Manager system through a digital station module. Examples of analog voice 
devices are analog telephones or answering machines. Examples of data communication devices 
are modems and fax machines. 
The ATA 2 provides on-premise service only (unexposed plant only).
This section includes:
Understanding pre-installation requirements
Before you attempt to install an ATA 2 device, ensure that your system and environment meet the 
requirements listed in this section.
Environmental requirements
Line voltage (120 V)
102 – 132 V ac
Line voltage (230 V)
207 – 253 V ac
Temperature
0 – 50°C (32 – 122°F)
Relative humidity
5% – 95% non-condensing
Bridge taps
Not allowed between the Business Communications Manager system 
loading coils and Business Communications Manager ATA2
Operating requirements
Ringing signal (North America): 
Frequency Voltage:
20 Hz ± 1 Hz
80 V rms ± 10%
Ringing signal (Europe): 
Frequency voltage:
25 Hz ± 1 Hz
75 V rms ± 10%
Ringer equivalence number
3