Chapter 17 Adding or replacing a cooling fan
N0008587  01
Troubleshooting fan operation
There are two LEDs on the front of the BCM1000 and one on the front of the expansion cabinet 
that can be used to assess fan function. Refer to 
.
Figure 103   Business Communications Manager operational LEDs
 describes the possible states of the fan and temperature LEDs.
Removing a fan from the BCM1000
The BCM1000 can have one or two fans. 
If the BCM1000 has two fans, before you shut down the system, determine which fan has failed.
1
If you still have access to the Unified Manager, shut down the system using the Shutdown 
command. For details refer to 
. Otherwise, 
skip to step 2.
2
Set up the BCM1000 for maintenance, as described in 
.
3
Attach one end of the grounding strap to your wrist and the other end to a grounded metal 
surface.
Table 42   
Fan and temperature LEDs on the server
LED Label
Description
Green LED On
Red LED On (Only)
Temperature
Temperature is below threshold. Temperature is in alarm status.
One of the problems could be that one of 
the fans has failed.
Fans
All installed fans are working
There is a problem with a minimum of 
one fan.
Operation LEDs
Temperature
Fan