Panasonic PT-EZ570EL Benutzerhandbuch

Seite von 118
About indicator status
ENGLISH - 
91
Maintenance
When there is a problem with internal power
 
J
The status of the indicator is displayed with the following symbols.
: Off, : On, : Flashing, „
Off or On or Flashing
Indicators
Status of the projector
<ON(G)/
STANDBY(R)>
Green/Red/
Orange
<TEMP>
Red
<FILTER> 
Orange
<SHUTTER/
AV MUTE>
Blue
<LAMP>
Orange
/
/
*
1
*
1
*
1
*
1
*
1
A problem has been detected within the 
projector.
The projector will not turn back on even when 
pressing the <POWER ON> button on the 
remote control or the <
> button on the side 
control. Remove the power plug from the outlet, 
and plug it back in again.
If the power turns off, or the indicator turns on 
or flashes again, remove the power plug from 
the outlet and contact your dealer to request an 
inspection and repair. Do not leave the projector 
plugged in with the indicator on or flashing. 
Doing so may cause a fire or electric shock.
*1: The indicator will flash in approximately 0.5-second intervals.
When there is a problem with the air filter
 
J
The status of the indicator is displayed with the following symbols.
: Off, : On, : Flashing, „
Off or On or Flashing
Indicators
Status of the projector
<ON(G)/
STANDBY(R)>
Green/Red/
Orange
<TEMP>
Red
<FILTER> 
Orange
<SHUTTER/
AV MUTE>
Blue
<LAMP>
Orange
/
„
*
1
/„*
1
„
*
1
„
*
1
„
*
1
The indicator notifies you when the time set 
with [Filter counter timer] has been reached. 
Replace the air filter. (Filter replacement icon 
will be shown at the top right of the screen 
simultaneously.*
2
)
Alternatively, the indicator notifies you when 
[Filter counter remaining] becomes 0%. 
Replace the air filter. 
//
*
2
*
2
*
2
*
2
When the air filter unit isn't installed, the 
projector is forced shutdown. Install the air 
filter unit.
*1: The indicator will change according to different conditions, regardless of the status of other indicators.
*2: The indicator will flash in approximately 0.5-second intervals.
*3:  When [Display] (
Æ
 page 63) is set to [Off], the freeze function (
Æ
 page 43) or shutter function (
Æ
 page 41) will not be 
displayed on the screen during operation.