Panasonic D6KE Benutzerhandbuch

Seite von 42
E
NGLISH - 28
Maintenance
Monitor Lamp indicators
If a problem should occur with the projector, the indicators will inform you. Manage the indicated problems as follow.
1. Confirm the status of all indicators and projector, and switch off the projector in proper way.
2. Find out the cause of the problem by status of each indicator.
3. Follow the instruction for each indication below and solve the problem.
4. Turn on the projector in the correct way and confirm the indicator is not indicating a problem any longer.
 LAMP1/LAMP2 indicator
 TEMP indicator
Managing the indicated problems
NOTE:
• If no problem is found or the problem remains, do not turn on the projector. Instead contact your nearest dealer.
Lamp 
indication
Information
Check point
Remedial measure
Lighting in red
Indicates the time for 
replacing the lamp unit
• Did you notice a “REPLACE 
LAMP
” message on the screen 
when turning on the projector 
power supply?
• This lamp monitor lights up when the lamp 
unit used hours have reached 1 800* hours. 
Request the dealer to replace the lamp unit.
* 2 800 hours for PT-D5000E only.
Blinking in red 
once
Lamp unit is not installed.
• Check the lamp unit 
compartment.
• Install the lamp unit.
• When lamp unit is installed and still having 
the indicator lights, contact to the dealer.
Blinking in red 
3 times
Error is detected in the 
lamp circuit.
• Did you turn the power back on 
immediately after turning it off?
• Wait until the lamp has cooled off, and then 
turn on the power.
• Some error has arisen in the 
lamp circuit.
• Check for fluctuation (or drop) in 
the source voltage.
• Turn off the POWER switch of the projector 
properly and contact your nearest dealer.
Lamp 
indication
Information
Check point
Remedial measure
Lighting in red
Warm-up status
• Did you turn on the power when 
the ambient temperature was 
lower than approx. 0 °C (32 °F)?
• Wait about 5 minutes in the current status.
• Install the unit in a location having an 
ambient temperature from 0 °C (32 °F) - 
45 °C (113 °F).
High temperature inside. 
(WARNING)
• Check the ventilation port is 
blocked.
• Is the room air temperature too 
high?
• Was the temperature warning 
indication displayed?
• Remove the object that is blocking the 
ventilation port.
• Move the projector to a temperature of 0 °C 
(32 °F) - 45 °C (113 °F) and the humidity of 
20 % to 80 % (no condensation).
• Turn off the POWER switch of the projector 
in proper way and contact the dealer.
Blinking in red 
once
The filter is excessively 
dirty and the ventilation is 
poor.
Blinking in red 
twice
High temperature inside. 
(Standby condition)
Blinking in red 
3 times
Cooling fan has been 
stopped.
• Turn off the POWER switch of the projector 
in proper way and contact the dealer.
STANDBY(RED)/
STANDBY(RED)/
   ON(GREEN)
   ON(GREEN)
LAMP
LAMP
TEMP
TEMP
FILTER
FILTER
STANDBY(RED)/
STANDBY(RED)/
   ON(GREEN)
   ON(GREEN)
LAMP
LAMP
TEMP
TEMP
FILTER
FILTER
Indicators
Power indicator
Lamp1 (LAMP1) indicator
Lamp2 (LAMP2) indicator
Temperature (TEMP) indicator
Filter (FILTER) indicator