BASIC OPERATION
Static Convergence Adjustment
Adjust for the red and blue CRTs to place their pattern on top of the
green test pattern (center only).
NOTE: The static convergence adjustment should be performed for
R and B CRT. Carry out the adjustment after displaying an active
image for 20 minutes or more.
Proceed as follows:
1 Press the OPERATE button.
• The “OPERATE” menu is displayed.
2 Use the CURSOR
or
button to highlight the “6/STATIC”
line and then press ENTER to display the STATIC adjustment
screen. You can also select the STATIC adjustment screen
directly by pressing the INPUT “6” button , or by pressing the
STATIC button on the remote control.
• The CROSS-HAIR test pattern will be automatically displayed.
3 Press the R or B button to display the pattern to be aligned with
the Green pattern (as used a reference color).
• You can turn on or off each CRT beam (R and B) separately.
4 Hold down the CTL button then select the CRT you wish to
adjust with the R and B buttons.
5 Align the center of the Red or the Blue pattern with the center of
the Green pattern using the CURSOR buttons.
• The CURSOR
or
button moves the pattern right or left.
The CURSOR
or
button moves the pattern up or down.
6 Repeat steps  3 to  5 for the other CRTs if necessary.
7 To end this adjustment, press the END button.
• Whenever the END button is pressed, the screen changes in this
order:
“OPERATE” menu 
 Source screen
–   O P E R A T E   –
1   /   P I C T U R E
2   /   P O S I T I O N
3   /   S O U N D
4   /   I N P U T   S E L E C T
5   /   S O U R C E   I N F O
6   /   S T A T I C
7   /   C L O S E D   C A P T I O N
8  / T I M E R
+ 1 0 %
– 1 0 %
V
H
C O N V E R G E N C E
– S T A T I C –
C R T   – R –
Red or Blue
Green