Cabletron Systems 04-0053-01 Benutzerhandbuch

Seite von 133
8-4   SmartSwitch ATM User Guide
Port Clock Configuration
  ATM Filtering and Clocking
By default, the clock mode for all SmartSwitch 6500 ports is 
local
. Use the 
set portclockmode
 command to change 
a ports clocking source. For example, the following sets port 
5a3
 into loopback mode.
SmartSwitch # set portclockmode
PortNumber(ALL)                           : 5a3
PortClkMode(local)                        : loop
SmartSwitch #
Note
Never configure two connecting port to both be in loopback mode. Without at 
least one of the connecting ports generating a clocking signal, connectivity will go 
out of sync and communication will be lost.
8.2.1
Network Clocking
Network clocking allows your SmartSwitch 6500 to obtain an external, high-quality, precise clocking signal and make 
it available for use by all ports. Typically, network clocking is configured when a high-quality clock signal is available 
(for example from a service provider connection) and the SmartSwitch is supporting traffic from applications that are 
time-sensitive, such as voice and video. The port connected to the high-precision clock signal is specified as the 
network source using the 
set networkclock
 command. When set, the port is essentially placed in loopback mode, 
however, the port also places the incoming, high-precision signal on the SmartSwitch 6500’s backplane, where it 
becomes available to all other ports.
The following is an example of network clocking configuration. It is assumed in this example that the SmartSwitch 
6500 is connected through port 
7a1
 to a service provider’s switch that produces a high-precision clocking signal.
1.
Use the 
set networkclock
 command to specify the port through which the network clocking signal 
is to be obtained
SmartSwitch # set networkclock
PortNumber(none)                          : 7a1
SmartSwitch #
2.
Use the 
set portclockmode
 command to instruct ports (either all ports or on a per-port basis) to use 
the clocking signal obtained from port 
7a1
SmartSwitch # set portclockmode
PortNumber(ALL)                           : 
— In this example, we set all ports to use the network clock
PortClkMode(local)                        : network
SmartSwitch #
Once the 
set portclockmode
 command is entered with the 
PortClkMode
 parameter set to 
network
, the ports specified 
on the SmartSwitch 6500 now use the clocking signal received on port 
7a1 
as their port clock source.