Table 22: Inventory of Components Provided with an EX2200 Switch (continued)
Quantity
Component
8
Mounting screws
4
Rubber feet
1
RJ-45 cable and RJ-45 to DB-9 serial port adapter
Related
Documentation
Mounting an EX2200 Switch
You can mount the switch:
On two posts in a 19-in. rack or cabinet by using the mounting brackets provided with
the switch.
On four posts in a 19-in. rack or cabinet by using the separately orderable four-post
rack-mount kit.
In a position recessed 2 in. from the front of a 19-in. rack or cabinet by using the
2-in.-recess front brackets in the separately orderable four-post rack-mount kit. You
can mount the switch in this recessed position on two-post or four-post racks and
cabinets.
On a desk or other level surface by using rubber feet. The switch is shipped with four
rubber feet to be used to stabilize the chassis on a desk or other level surface.
On a wall by using the separately orderable wall-mount kit.
WARNING:
When mounting an EX2200 switch chassis in a vertical position, orient
the front panel of the chassis downward to ensure proper airflow and
meet safety requirements in the event of a fire.
When wall mounting Power over Ethernet (PoE) models (EX2200-24P
and EX2200-48P), install the wall-mount baffle above the units to reduce
the risk of objects or substances falling into the air exhaust or power
supply, which could cause a fire.
The holes in the mounting brackets are placed at 1 U (1.75 in. or 4.45 cm.) apart so that
the switch can be mounted in any rack or cabinet that provides holes spaced at that
distance.