TIMING CHARACTERISTICS
I
2
C-bus load conditions: 4 k
Ω
 pull-up resistor to +5 V; 200 pF capacitor to GND;
all values are referenced to V
IH
= 3 V and V
IL
= 1.5 V; see Fig.4.
Note
1. Timing t
HD;DAT
 deviates from the I
2
C-bus specification. After reset has been activated, a delay of 50
µ
s must occur
before transmission may be resumed.
SYMBOL
PARAMETER
CONDITIONS
MIN.
TYP.
MAX.
t
BUF
time bus must be free before start
4.7
µ
s
t
SU;STA
set-up time for start condition
4.7
µ
s
t
HD;STA
hold time for start condition
4.0
µ
s
t
LOW
SCL and SDA LOW time
4.7
µ
s
t
HIGH
SCL HIGH time
4.0
µ
s
t
r
SCL and SDA rise time
1.0
µ
s
t
f
SCL and SDA fall time
0.3
µ
s
t
SU;DAT
data set-up time (write)
250
ns
t
HD;DAT
data hold time (write)
note 1
1.0
µ
s
t
SU;ACK
acknowledge set-up time
2
µ
s
t
HD;ACK
acknowledge hold time
0
µ
s
t
SU;STO
set-up time for stop condition
4.7
µ
s
Fig.4  I
2
C-bus timing diagram.
handbook, full pagewidth
MLD005
SDA
(WRITE)
SCL
t BUF
t SU; STA
t HD; STA
t LOW
t f
t r
t HD; DAT
t SU; ACK
t HD; ACK
t LOW
t SU; STO
t HIGH
t SU; DAT