Pelco c1515m-a Benutzerhandbuch
28
Pelco Manual C1515M-A (11/01)
MULTIPLE M DEVICES: REMOTE CONNECTION
Use a remote connection when the distance from the CM6800 is greater than 6-feet (1.8 m).
1.
Connect each ALM2064 and REL2064 unit to a wall block with a 6-foot (1.8 m) straight
cable (supplied with the CM6800). You can connect a maximum of two ALM2064 units
and two REL2064 units to the CM6800.
cable (supplied with the CM6800). You can connect a maximum of two ALM2064 units
and two REL2064 units to the CM6800.
2.
If you are connecting a KBD960, connect it to the CM9505UPS with the straight cable
supplied with the keyboard. Then connect the CM9505UPS to a wall block with a
6-foot (1.8 m) straight cable (supplied with the CM6800). You can connect a maximum
of two KBD960 keyboards to the CM6800.
supplied with the keyboard. Then connect the CM9505UPS to a wall block with a
6-foot (1.8 m) straight cable (supplied with the CM6800). You can connect a maximum
of two KBD960 keyboards to the CM6800.
3.
Connect the wall blocks to a final wall block. If additional wall blocks are needed, order
part number CON12J008Z03G0Z.
part number CON12J008Z03G0Z.
4.
Connect the terminal wall block to COM 3 on the CM6800 using a 6-foot (1.8 m)
straight cable (supplied with the CM6800).
straight cable (supplied with the CM6800).
ALM2064
REL2064
KBD960
STRAIGHT CABLE
(SUPPLIED)
STRAIGHT CABLE
TO CM9505UPS
(SUPPLIED)
TO CM9505UPS
(SUPPLIED)
CONNECT THROUGH
THE “OUT” PORT
THE “OUT” PORT
KBD960
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
ALM2064
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
REL2064
RJ-45 PIN-OUTS
1 Tx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
2 Tx-
3
4
5
6
7 Rx-
8 Rx+
COM 1
1
2
3
4
5
6
7
8
16
8
7
6
32
31
4
3
VIDEO OUTPUTS
120/230~
50/60 HZ
50/60 HZ
25 WATTS
COM
ALARM
1 2 3 4 5 6 7 8
CONTROL
PTZ
OUT
A T
+
T
-
R
+
R
-
T
+
T
-
R
+
R
-
B
1
2
F
3
CONNECT THROUGH
THE “OUT” PORT
THE “OUT” PORT
3
4
2
1
5
6
7
8
3
4
2
1
5
6
8
7
8
5
6
7
4
1
3
2
3
4
1
2
8
6
7
5
STRAIGHT CABLE
(SUPPLIED)
CM6800 COM 3
RJ-45 PIN-OUTS
1 Rx+
2 Rx-
3
4
5 GND
6
7 Tx-
8 Tx+
2 Rx-
3
4
5 GND
6
7 Tx-
8 Tx+
COM 3
DEFAULT SETTINGS:
M, RS-485, 19200 BAUD, NO PARITY, 8 DATA BITS, 1 STOP BIT
MAX # OF DEVICES = 6
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16pF PER FT (pF = PICOFARDS)
DEFAULT SETTINGS:
M, RS-485, 19200 BAUD, NO PARITY, 8 DATA BITS, 1 STOP BIT
MAX # OF DEVICES = 6
MAXIMUM DISTANCE FROM CM6800 = 3,940 FT (1,200 M)
USING 24 AWG COPPER, UNSHIELDED TWISTED PAIR; 16pF PER FT (pF = PICOFARDS)
Figure 20. Connecting Multiple M Devices – Remote Connection
Installation:
M Devices