P
AGE
 121
V
ERSION
 1.0, M
ARCH
 2003
 
IBM eServer BladeCenter 
Fibre Channel Switch Module
Integration Checklist
The following steps must be completed to successfully merge IBM BladeCenter and QLogic fabrics. 
The remainder of this section provides detailed instructions and examples.
ATTENTION!!
Backup the current configuration prior to performing the following steps so that the 
configuration is available if something goes wrong.
Disruptions in the fabric can occur as a result of performing the following steps. Therefore, 
it is recommended that these changes be done during down time or off-peak hours.
Verify that the correct version of switch firmware is installed on each switch 
Ensure that each switch has a unique Domain ID 
Set all switches to the appropriate timeout values 
.
Ensure that all Zone set and Zone names are unique and conform to ANSI T11 standards 
.
Ensure that all QLogic switches are configured for Merge Active Zonesets Only or SW2 mode, 
as appropriate 
.
Verify that the fabrics have successfully merged 
.
Configuration Limitations
No limitations exist when merging IBM BladeCenter and QLogic fabrics; all features are fully 