Page 12 of 102
 
 
                     
Applying Power 
 
 
 
 
 
 
 
 
 
 
 
The M12 A coded power connector is keyed, where the mating connection from the power supply 
can be made only when the male and female ends are lined up properly.
 
When the power is first connected all LED’s will flash ON Momentarily. 
Verify the Power LED stays ON (GREEN). 
 
Note:    Either  V
1
  or  V
2
  can  be  connected  to  power  for  minimal  operation.    For  redundant  power 
operation, V
1
 and V
must be connected to separate DC Voltage sources. The power cord should be 
limited to less than 10 meters in order to ensure optimum performance. 
 
Recommended 24V DC Power Supplies, similar to: 
 
100VAC/240VAC: 
 
N-Tron NTPS-24-1.3, DC 24V/1.3A