Netgear FS102 Benutzerhandbuch

Seite von 17
Model FS102, Model FS104, Model FS108 Fast Ethernt Switch Installation Guide
Symptom
Cause 
Solution
Green Link LED is 
off on an active 
port.
Port connection is 
not functioning.
Make sure the attached device is powered and there is 
a proper UTP connection at that end.
Make sure the network adapter card installed in the 
PC is in working condition. Verify that the network 
adapter card is100 Mbps capable and that the 100 
Mbps LED and Link LEDs are on at the network 
adapter card in the PC.
Make sure the proper cable is installed, and check for 
miswired cable pairs or loose connectors.
Green Link LED is 
intermittent on an 
active port.
Port connection is 
not functioning.
Make sure the port termination at both the switch and 
the device end is correct. Check the crimp on the RJ-
45 connectors. In a Fast Ethernet operation, the 
quality of the crimp on the connector is important. It is 
also important that only Category 5 cable is used and 
that it is certified for 100 Mbps operation.
Make sure the length of the UTP cable from the switch 
to the device does not exceed 328 feet (100 meters).
Using cable test equipment, make sure the cable 
meets the crosstalk, attenuation, and impedance 
specifications as required by the 100BASE-TX 
standard. Refer to “Cable and Connector Information” 
for information about cable specifications.
Green Link LED is 
off on ports 1 or 2 
on the Model 
FS102 switch, port 
4 on the Model 
FS104 switch, or 
port 8 on the 
Model FS108 
switch.
Port connection is 
not functioning.
Check the Normal/Uplink push button on the front 
panel. 
If you are using a straight-through cable connected to 
a PC or other MDI-wired device, make sure the 
Normal/Uplink push button is set in the Normal 
position.
If you are using a straight-through cable connected to 
a router or another switch, make sure the Normal/
Uplink push button is set in the Uplink position.
Try the alternate position of the Normal/Uplink push 
button to turn the Link LED on.
Refer to “Cable and Connector Information” for cable 
information.
Green 100 Mbps 
LED is off when 
operating in a Fast 
Ethernet network.
Port is operating in 
10 Mbps mode.
Make sure the adapter card is capable of 100 Mbps 
operation and set for 100 Mbps operation if it is not 
autosensing.
Green Link LED is 
on and Green FDX 
LED is off when 
connected to a full 
duplex network.
Port is operating in 
half-duplex mode.
Make sure the duplex switch on the Model FS102/
FS104/FS108 switch is set for full-duplex operation. 
Make sure the connected device is capable of full-
duplex transmission.
Troubleshooting Information