Enterasys Networks D2G124-12P Benutzerhandbuch

Seite von 496
clear logging application
12-8 Logging and Network Management
Defaults
If level is not specified, none will be applied.
Mode
Switch command, read‐write.
Example
This example shows how to set the severity level for SNMP to 4 so that error conditions will be 
logged for that application.
D2(rw)->set logging application SNMP level 4
clear logging application
Use this command to reset the logging severity level for one or all applications to the default value 
of 6 (notifications of significant conditions).
Syntax
clear logging application {mnemonic | all}
level level
(Optional) Specifies the severity level at which the server will log 
messages for applications. Valid values and corresponding levels are:
1 — emergencies (system is unusable)
2 — alerts (immediate action required)
3 — critical conditions
4 — error conditions
5 — warning conditions
6 — notifications (significant conditions)
7 — informational messages
8 — debugging messages
Table 12-38
Mnemonic Values for Logging Applications 
Mnemonic
Application
CLIWEB
Command Line Interface and Webview management
SNMP
Simple Network Management Protocol
STP
Spanning Tree Protocol
Driver
Hardware drivers 
System
Non-application items such as general chassis management
Stacking
Stacking management (if applicable)
UPN
User Personalized Networking
Router
Router