Enterasys Networks D2G124-12P Benutzerhandbuch

Seite von 496
show system hardware
D-Series CLI Reference 2-13
show system hardware
Use this command to display the system’s hardware configuration.
Syntax
show system hardware
Parameters
None.
Defaults
None.
Mode
Switch command, read‐only.
Example
This example shows how to display the system’s hardware configuration. Please note that the 
information you see displayed may differ from this example.
D2(su)->show system hardware
        SLOT 1 HARDWARE INFORMATION
        ---------------------------
        Model:                          D2G124-12
        Serial Number:                  777777777777
        Vendor ID:                      0xbc00
        Base MAC Address:               00:11:88:B1:76:C0
        Hardware Version:               BCM56514 REV 1
        FirmWare Version:               01.00.00.0052
        Boot Code Version:              01.00.42
show system utilization
Use this command to display detailed information about the processor running on the switch, or 
the overall memory usage of the Flash and SDRAM storage devices on the unit, or the processes 
running on the switch. 
Syntax
show system utilization {cpu | storage | process}
PWR2-B Status
Operational status for the power supply connected to PWR1-B on the switch.
Fanx-Status
Operational status of the fan(s). (This output not in use for the D2.)
Uptime d,h:m:s
System uptime.
Logout
Time an idle console or Telnet CLI session will remain connected before timing 
out. Default of 5 minutes can be changed with the set logout command (“
Table 2-6 show system Output Details (Continued)
Output
What It Displays...