3com 3000 TX Benutzerhandbuch

Seite von 144
Unit Overview — Front
1-7
100BASE-TX Ports
The Switch 3000 TX has eight Fast Ethernet 
100BASE-TX RJ45 ports configured as MDIX 
(cross-over), which provide connection to other Fast 
Ethernet devices such as the SuperStack II Switch 
1000. The maximum segment length is 100m 
(328ft) over category 5 UTP or STP cable.
As these ports are configured as MDIX (cross-over), 
you need to use a cross-over cable to connect to 
devices whose ports are MDIX-only. Most of the 
100BASE-TX ports in 3Com devices are MDIX-only.
LEDs
 describes the LED behavior on the Switch 
3000 TX. For more details about corrective action in 
the event of a problem, refer to 
 on 
.
Table 1-1   LED behavior
LED
Color
Indicates
Port Status LEDs (ports 1 – 8)
Packet
Yellow
Frames are being transmitted/received 
on the port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Off
Link is not present.
Plug-in Module Status LEDs (port 9)
Packet
Yellow
Frames are being transmitted/received 
on the Plug-in Module port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Green flashing 
(long on, short off)
Refer to the “SuperStack II Switch ATM 
OC-3c Module User Guide”.
Yellow
Plug-in Module has failed its Power On 
Self Test (if the MGMT LED is flashing 
yellow), or the agent software of the 
Plug-in Module is not installed correctly.
Yellow flashing
Plug-in Module is not recognized.
Off
Link is not present or the Plug-in Mod-
ule is not installed in the Switch.
Unit Status LEDs
Power
Green
Switch is powered-up.
MGMT Green
Switch is operating normally.
Green flashing
Switch or Plug-in Module is either 
downloading software or initializing 
(which includes a Power On Self Test).
Yellow
Switch has failed its Power On Self Test.
Yellow flashing
Plug-in Module has failed its Power On 
Self Test.