Troubleshooting Chart
Troubleshooting Chart
Symptom
Action
Cannot connect using 
Telnet, Web browser, 
or SNMP software
Be sure to have configured the agent with a valid IP 
address, subnet mask and default gateway.
Check that you have a valid network connection to the 
switch and that the port you are using has not been 
disabled.
Check network cabling between the management station 
and the switch.
If you cannot connect using Telnet, you may have 
exceeded the maximum number of concurrent Telnet 
sessions permitted. Try connecting again at a later time. 
Cannot access the 
on-board 
configuration 
program via a serial 
port connection
Be sure to have set the terminal emulator program to 
VT100 compatible, 8 data bits, 1 stop bit, no parity and 
19200 bps. 
If the switch is configured for Auto (baud rate detection), 
the terminal emulator program must be set at 
2400~19200 baud, 8 data bits, 1 stop bit, no parity, and 
flow control set to none. Also, you must first press the 
Enter key once to set the data rate and initialize the 
connection.
Check that the null-modem serial cable conforms to the 
pin-out connections provided in Appendix B. 
Forgot or lost the 
password
Contact SMC Technical Support for help.