Special Applications, cont’d
PRELIMINAR
Y
MGP 464 • Special Applications
6-4
5
Repeat step 4 for every input on the matrix switcher that will be displayed 
on the output screen via the MGP, saving the settings for each input as Input 
Preset 2, 3, etc.  
N
  Each input preset must be saved with the same number as the input on the 
matrix switcher.
6
Synchronize the MGP 464 to the matrix switcher as follows:
a
.  Open the Windows-based control software.
b
.  From the Tools menu, select Sync MGP 464 to Matrix Switcher... .  The 
Sync MGP 464 to Matrix Switcher window opens.
c
.  In the IP Address field, enter the matrix switcher’s IP address.
d
.  Click Connect To Matrix button.  The switcher’s matrix size is displayed 
to the right of the button, and its input-output ties are displayed in the 
Matrix Status section below.
e
.  From the drop-down menu in the MGP 464 Input #1 field, select the 
number of matrix switcher output to which you connected the MGP’s 
input 1 in step 1.
f.
  Repeat step e for MGP inputs 2 through 4, making sure to select the 
number of the switcher’s output connector to which you attached the  
MGP input with which you are working.
g
.  Click Take to tie the MGP inputs to the selected switcher outputs.
h
.  Click Close to close the Sync MGP to Matrix Switcher window.
   
Sync MGP 464 to Matrix Switcher window with input ties to switcher