Redundant MSM Activity (BlackDiamond 12804 Switch)
The BlackDiamond 12804 switch can operate with a single MSM installed, providing full bandwidth 
with this single MSM. When you install a second MSM, one of the MSMs operates as the primary, and 
the other becomes the secondary or backup.
The primary MSM is responsible for upper-layer protocol processing and system management 
functions. The MSMs in the BlackDiamond 12804 switch are not load sharing. MSM(A) or MSM(B) 
handles packets while the other MSM is idle.
When you save the switch configuration, it is saved to all MSMs.
Selection of the primary MSM occurs automatically. The following examples describe the selection 
process:
When a BlackDiamond 12804 switch boots with two MSMs installed, the MSM in slot 3/A becomes 
the primary. 
If a switch is operating with one MSM and a second MSM is added to the switch after it has been 
powered up, the added MSM becomes the secondary. MSMs that operate as secondary, or backup, 
MSMs can be inserted and removed without disrupting network services.
If you remove the primary MSM while the switch is operating, the secondary MSM performs a soft 
reset and then becomes the primary MSM.
For example, if you have a BlackDiamond 12804 switch with a primary MSM in slot 3/A and a 
secondary MSM in slot 4/B, and you remove the primary MSM from slot 3/A, the secondary, or 
backup, MSM in slot 4/B becomes the primary.
MSM LEDs
 describes the LED activity on the BlackDiamond 12800 series MSMs.
Table 5: BlackDiamond 12800 Series MSM LEDs
LED
Color
Meaning
SYS
Green blinking
Amber blinking
Normal operation.
Diagnostic tests are running on the module. The LED resets if the 
diagnostics are terminated. The LED returns to blinking amber if 
another diagnostic test is started.
Amber steady
Diagnostic failure has occurred.
Off
Switch is not receiving power.
MSTR
Green steady
Module is operating as primary MSM.
Amber
Module is operating as secondary, or backup, MSM.
Green blinking
Power-on self-test (POST) is running.
Off
Normal operation for diagnostics.
ERR
Amber
A critical software error has been logged since power-up.
Off
Normal operation.
ENV
Green
Environment (temperature, fan, power supply) is operating properly.
Amber
Environmental failure has occurred.