 shows the pinouts for a 9-pin to 25-pin (RS-232) null-modem cable.
Table 29: DC PS Model #65022 (325 W DC PSU) 
For the BlackDiamond 12802 switch
Minimum configuration
2 power supplies
Full configuration
4 power supplies
Input
Nominal input voltage: –48 V
, –60 V
, 15 A maximum
Operational voltage range: –40 V to –72 V
Maximum input amperages: 
10 A @ –40 V
 (low-line)
8 A @ –48 V
7 A @ –60 V
 (high-line)
Maximum in-rush current: 8 A
Input circuit protection: 15 A 
Wire harness provided by Extreme Networks with each power supply. 
Extreme part number 4340-00028 
Minimum wire size: 14 AWG (1.3 mm
2
) copper stranded
(pre-approved cord set for county of use)
Connector: Molex connector PN 42816-0312
Connector pins: Molex connector pins PN 42815-0032
Output
DC Output:
48 V 
, 6 A/ 12 V 
 
2.5 A/7 VSB 0.75 A
Output power (W): 325 W
Operating conditions
Operating temperature: 0° C to 40° C
Storage temperature: –40° C to 70° C
Operating humidity: 10% to 90% relative humidity, non-condensing
Operational shock: 30 m/s
2
 (3 g)
Table 30: Pinouts for the DB-9 Console Connector
Function
Pin Number
Direction
DCD (data carrier detect)
1
In
RXD (receive data)
2
In
TXD (transmit data)
3
Out
DTR (data terminal ready)
4
Out
GND (ground)
5
-
DSR (data set ready)
6
In
RTS (request to send)
7
Out
CTS (clear to send)
8
In