Key Setting Operations With the Key Control Block
1
Using the M/E delegation buttons in the key control block, press the [M/
E1] button, setting it on.
2
Using the key delegation buttons in the key control block, press the 
[KEY1] button, setting it on.
This assigns the key control block to M/E-1 key 1.
Parameter adjustment with the knobs
When the button for a function requiring parameter settings is pressed (that is, 
on), you can set the parameters with the four knobs. If there are more than four 
values to be assigned to the knobs, the [MORE] button lights amber. At this 
point, press the [MORE] button, which turns green, to assign the fifth and 
subsequent parameters to the knobs, so that the parameter settings can be made.
Selecting the key type
To select the key type, press one of the key type selection buttons in the key 
control block.
[LUM] button: luminance key
[LIN] button: linear key
[CRK] button: chroma key
[CVK] button: color vector key
[PTN] button: key wipe pattern key
When using a wipe pattern key as the key type, in the <Key Type> group 
of the Type menu for the keyer, select [Wipe Pattern] and make the 
settings.
For an overview of the key types, see page 46.
The button you pressed lights green, and you can now adjust the parameters 
with the knobs. The display beside each knob shows the first letter of the 
parameter name and the three-digit setting value.
• When the [LUM] or [LIN] button is lit green
Knob
Parameter
Adjustment
Setting values
1
Clip
Reference level for generating the 
key signal
+109 to –7
2
Gain
Key sensitivity
–100 (shown as 
00) 
to +100
3
Density
Key density
0 to 100
4
Filter
Filter coefficient
1 to 9