Fujitsu MB88121 SERIES Benutzerhandbuch

Seite von 73
SK-91F467-FLEXRAY V1.1 
Jumpers and Switches  
© Fujitsu Microelectronics Europe GmbH 
- 31 -  
FMEMCU-UG-910017-11 
3.7  CAN0 – CAN2 
Three high-speed CAN-transceivers (PCA82C250) are on-board to connect all available on-
chip CAN to 9-pin D-Sub connectors (X9, X10 and X11). 
JP82  Connects MCU RX0 to CAN transceiver U15 
JP83  Connects MCU TX0 to CAN transceiver U15 
JP87  Connects MCU RX1 to CAN transceiver U18 
JP88  Connects MCU TX1 to CAN transceiver U18 
JP89  Connects MCU RX2 to CAN transceiver U19 
JP90  Connects MCU TX2 to CAN transceiver U19 
Jumper 
Setting 
Description 
ON (closed) 
CAN0 RxD connected to MCU 
JP82 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
CAN0 TxD connected to MCU 
JP83 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
CAN1 RxD connected to MCU 
JP87 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
CAN1 TxD connected to MCU 
JP88 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
CAN2 RxD connected to MCU 
JP89 
OFF (open) 
No connection to the microcontroller 
ON (closed) 
CAN2 TxD connected to MCU 
JP90 
OFF (open) 
No connection to the microcontroller 
Default: grey 
Table 3-15: CAN-MCU connection 
 
3.8  LIN / RS-232 UART 
There are three UART connectors X1, X4 and X8 (9-pin D-Sub) on-board, which can be 
used for RS-232 or LIN communication (to get information in detail about pin usage, please 
refer to chapter 4.2 UART / LIN Connector (X1, X4, X8)). The LIN transceiver needs to be 
configured as LIN-master or LIN-slave.