Quick Start 
H3C S3100-SI Series Ethernet Switches
Chapter 3  Installation
 
3-3 
3.1.2  Mounting the Switch on a Workbench 
When a 19-inch standard cabinet is not available, you can simply 
place the switch on a clean workbench. When doing so, you should 
ensure: 
z
 
The workbench is stable and well grounded. 
z
 
A clearance of about 10 cm is reserved around the switch for 
heat dissipation. 
z
 
No heavy object is placed on the switch. 
z
 
The S3100-SI series are designed with no fan. Therefore, 
you should install them in a drafty environment, and keep at 
least 1.5 cm vertical distances between the neighboring 
devices if you need to stack the switches one upon another. 
3.1.3   Wall-Mount 
You can hang the S3100-8T-SI and S3100-8C-SI Ethernet 
Switches against walls. 
The wall can be made of cement, wood, or drywall. 
Figure 3-2 and Figure 3-3 shows the recommended sizes (in mm) 
of the screws and anchor kits used for mounting: 
 