Aube Technologies TI054A-06-3W Benutzerhandbuch

Seite von 3
PROGRAMMABLE THREE-WAY SWITCH
MODEL TI054A-06-3W
FOR ALL LIGHTING SYSTEMS
MAXIMUM CHARGE MUST NOT EXCEED 500 W / 230 V
FOR A SINGLE POLE INSTALLATION
For a single pole installation no wire is connected to terminal “1”.
INSTALLATION
This programmable switch may be used in either a single pole or a mul-
tiple pole switch installation.
Multiple pole switch installations with an electronic switch are different
from  conventional  installations.  Read  the  wiring  instructions  carefully
and select the one that applies to your situation.
You must follow the steps in the indicated order at all times:
Note: Please note that the two (2) “C” terminals on the programmable
switch have no polarity. They can both be used indiscriminately.
1. Cut the power supply at the main circuit breaker in order to avoid the
risk of electrical shock.
2. Remove and disconnect all existing three-way or regular switches. In
the case of a three-way switch, identify the wire connected to the “C”
or “common” terminal.
3. Connect each wire, as it is disconnected, to the programmable 
switch following the appropriate wiring diagram.
4. Close the main circuit breaker to reinstate the power supply.
FOR AN EXISTING THREE-WAY SWITCH INSTALLATION
To  replace  a  conventional  three-way  switch  by  a  programmable  one,
follow the following wiring diagram:
FUNCTION CHECK
Refer to the “START-UP”  section to start the programmable switch. Try
to activate the lighting using the remote switch and the programmable
switch.  If  everything  is  in  working  order,  the  installation  is  complete.
Otherwise, cut the power supply at the main circuit breaker and recon-
nect the connecting wire on the remote switch between the “common”
terminal and the other terminal.
FOR A NEW THREE-WAY INSTALLATION
For a new installation, you may use a single pole switch at the remote
location. Use the following wiring diagram:
Note: Note that the connecting wire supplied is not used in this installation.
START-UP
For the first trial under power, use a paper clip to push on the R button.
You should see the figures 0:00 flashing on the screen.
If nothing appears on the screen, check the following points:
a) The programmable switch fuse may not be installed properly or may
be defective.
b) If the programmable switch controls a lamp with its own switch, 
make sure that the latter is always “ON”.
The TI054A-06-3W three-way switch MAY be installed on EITHER of the
following lighting systems:
- Incandescent
- Halogen
- Low voltage halogen with transformer
- Fluorescent
It must not be installed on a motor or a charge exceeding 500 W.
The  “common”  wire  (phase)  that  you  identified  while  removing  the
existing three-way switch must be connected to one of the two “C” ter-
minals  on  the  programmable  switch.  Connect  the  other  two  wires
(black)  to  the  remaining  two  terminals  on  the  programmable  switch.
The  connecting  wire  supplied  will  be  added  to  the  remote  three-way
switch between the “common” terminal and the black wire connected to
terminal “C” on the programmable switch. Once the connection is com-
pleted,  correctly  install  the  switches  in  their  own  electrical  box  and
close the main circuit breaker to reinstate the power supply.
920-054-001-00-1-0   1/3