Barco DCS-200 Benutzerhandbuch

Seite von 170
DCS-200  •  User’s Guide
153
_K==oÉãçíÉ=`çåíêçä
Remote Commands
icbk
Description:  Sets the mode for the selected log.  When selected, the messages 
for that log will be written to flash every time interval specified in (LINT).
Command Format:  LFEN -l (log) -m (mode)
Parameters:  - l (log): 0-combined, 1-debug, 2-warning, 3-error
-m (mode): 0 - disable, 1 - enable
Query Format:  N/A
Query Response:  N/A
ifkq
Description:  Sets the time interval for writing the enabled logs to flash.
Command Format:  LINT -t (time interval)
Parameters:  -t (time interval): 1 - 60 seconds
Query Format:  N/A
Query Response:  N/A
il`hlrq
Description:  Controls the lockout mode of the front panel. With full lockout mode 
enabled, all keys and menu will be deactivated. The executive mode will lock out 
all but the input bus keys (1 through 8, SDI, and LOGO).
Command Format:  LOCKOUT -m (mode)  -f
Parameters:  -m (mode): 0 - disable, 1 - full lockout, 2 - executive mode 
(default: 0 - disable)
-f: Command from front panel
Query Format:  LOCKOUT -?
Query Response:  LOCKOUT -m (mode) -- min 0 -- max 2
lpq^q
Description:  Query only command for the output status type and format.
Query Format:  OSTAT  -?
Query Response:  OSTAT  -t "(output type)" -f "(output format)"
mobsfbt=
Description:  Query only command for the input, key and black button status on 
preview.  If the black, key, or scaler path is not present on preview, then these 
options are not returned.
Parameters:  -i (input): 1 - 9
-k: key on preview
-b: black on preview
-l: logo on preview
-a: A or B path of scaler input on preview