Minicom Advanced Systems 5UM20114 Benutzerhandbuch

Seite von 87
SMART CAT5 SWITCH 16 IP
.
 
35
 
gateway address and net mask. Before you connect Smart 16 IP to your local sub-
net, complete the corresponding configuration of your DHCP server.  
BOOTP - When selected, Smart 16 IP will contact a BOOTP (Bootstrap 
Protocol) server in the local sub-net to obtain a valid IP address, gateway address 
and net mask. 
IP address  
Static IP address in the usual dot notation.  
Subnet mask 
The net mask of the local network.  
Gateway IP address  
In case the Smart 16 IP should be accessible from networks other than the local 
one, this IP address must be set to the local network router's IP address.  
Primary DNS Server IP address  
IP address of the primary Domain Name Server. This may be left empty, however 
Smart 16 IP won't be able to perform name resolution.  
Secondary DNS Server IP address  
This address will be used in case the Primary DNS Server can't be contacted.  
Primary Time Server  
IP address of the primary NTP (Network Time Protocol) compliant timeserver. 
Smart 16 IP will synchronize its own absolute time with the timeserver's one. This 
is important for writing log entries and for the Dynamic DNS Service.  
Secondary Time Server  
This address will be used in case the Primary Time Server can't be contacted.  
Remote Console & HTTPS port  
Port number at which Smart 16 IP's Remote Console server and HTTPS server are 
listening. If empty the default value is used.  
HTTP port  
Port number at which Smart 16 IP's HTTP server is listening. If empty the default 
value is used.