61202022L1-1B
Equipment LOS
Condition: EQ LOS LED is illuminated.
1.
Verify that the cable from the CPE is in the 
CPE 
modular jack on 
the bottom/end of the CSU ACE.
2.
If all connections seem intact, use a BERT test set in the 
NET IN 
and 
NET OUT
 jacks to test the CPE.
Power On - Self Check Failure
Condition: NET LOS, EQ LOS, NET LB, and EQ LB all flash in uni-
son, continuously.
The unit has failed its internal self check. Return the unit to the 
ADTRAN Customer and Product Service (CAPS) Department as 
instructed on page 12.
EPROM Checksum Failure
Condition: NET LOS and EQ LOS Flash alternately with NET LB 
and EQ LB for the first 10 seconds after power up.
The unit’s EPROM has a bad checksum. Return the unit to the 
ADTRAN CAPs Department as instructed in the Product Support 
page on the back page of this manual.
MAINTENANCE
The T1 CSU ACE requires no routine maintenance. No repairs should 
be performed by the customer. Repair services can be obtained by re-
turning the unit to the ADTRAN Customer and Product Service 
(CAPS) department as instructed on page 12.