Installation Guide for the Intel Server Control
13
12. Click the Configure LAN button.
13. Enter the following on the BMC LAN Configuration (LAN) dialog box:
Option
Entry
Enable LAN Alerts:
Click to enable BMC LAN-alerts.
Enter New Password:
Enter the BMC LAN Configuration password, up to 16 characters. Default is
NULL. This will be used for all LAN connections in CSSU, DPC, PIC, and
BMC LAN-alerts.
Verify New Password:
Re-enter the BMC LAN Configuration password.
LAN Access Mode:
Full Access, which allows DPC and CSSU access via LAN. By default, LAN
access inside is disabled.
SNMP Community String:
Public (default) unless there is predefined SNMP host to receive SNMP traps
from BMC LAN-Alerts. Must be from 5 to 16 characters.
IP Configuration:
Static (default) unless you are using DHCP for IP hosting, then select DHCP.
Host IP Address:
Enter the IP address of the server if you are not using DHCP.
Gateway IP Address:
Enter the IP address of the router if you are not using DHCP.
Subnet Mask:
Enter the subnet mask of the hosts on the subnet if you are not using DHCP.
Alert IP Address:
Enter the IP address of the server to receive SNMP traps for the community
defined with the SNMP Community String. Enter 0.0.0.0 (default) if a
community is not defined.
14. Click Save, then Close.
15. Exit from the Server SSU.
16. Quit the Server Board CD-ROM menu.
Using the DPC Console Manager
1. Connect to the appropriate server.
2. Select Reboot Service Partition from the Action menu.
Using the Client SSU
1. Select (Re)Connect from the Server menu.