HP (Hewlett-Packard) ML110 G6 Benutzerhandbuch

Seite von 115
 
 
Removal and replacement procedures  66  
 
 
Power supply unit 
Located on the rear panel of the server is a single standard autoranging 300W power supply unit 
(PSU). 
PSU replacement warnings 
Observe the following reminders to reduce the risk of personal injury from electric shock hazards 
and/or damage to the equipment 
 
Installation of the power supply unit should be referred to individuals who are qualified to service 
server systems and are trained to deal with equipment capable of generating hazardous energy 
levels. 
 
DO NOT open the power supply unit. There are no serviceable parts inside it. 
To replace the power supply unit: 
1. 
Perform the pre-installation procedure. 
2. 
Remove the default power supply unit.  
a. 
Disconnect the power cables from the system board (1). 
Disconnect the power cables from the system drives.  
See 
b. 
While supporting the power supply unit with one hand, remove the four PSU screws from the 
rear panel (2). 
c. 
Remove the power supply unit from the chassis (3).