Replacing and Adding System Components
Replacing the power supply
The redundant power supply offers fault tolerance and hot-swap capabilities. 
However, if the power distribution board at the base of the power supply or 
some other part of the power supply fails, the entire power supply and its 
housing must be replaced. This type of failure is indicated by both power 
supply status LEDs flashing and an audible alarm, or the system will fail to 
power up.
 To replace the power supply:
1
Turn off the system and disconnect the power cord, modem cord (if 
installed), and all external peripheral devices.
2
Observe all safety and static electricity precautions. (See “Preventing static 
electricity discharge” on page 22.)
3
4
5
Disconnect the power supply connectors from all internal devices, 
including the 3.5-inch diskette drive, the CD drive, and all hard drives. 
Make a note of where everything is connected.
6
Disconnect the main power supply connector from the system board by 
pressing on the tab to release the connector, then gently pulling the 
connector from the board.