Communications Status LED’s 
Run
Node Off
Sys Err
LonSvc
Conf Err
Com Err
Rx
Tx
10/100
Act
 
 
LED 
Description 
Run 
When  the  SlotServer  is  powered  up,  this  light  will  start  flashing  after  approximately  2 
minutes. If this light does not flash, it is an indication that the firmware is not running, 
and that the SlotServer will not be operating. 
LonSvc 
This  light  will  flash  when  the  card’s  Neuron  chip  is  unconfigured,  and  will  extinguish 
when the SlotServer has been commissioned into a Network. 
NodeOff  
This light indicates that a device bound to the SlotServer on the LonWorks network is 
not communicating. Use the LonWorks Network Manager to troubleshoot the problem. 
Conf Err 
This light indicates an error in the configuration of the card. Since this model is shipped 
pre-configured,  this  light  should  never  come  on  unless  the  card  configuration  is 
tampered with 
Sys Err 
This light indicates that an unexpected operation state occurred. The light can be reset 
by  cycling  power  to  the  card.  If  the  error  re-occurs  persistently,  then  contact 
FieldServer  Technical  support  for  assistance  with  troubleshooting  after  setting  up  the 
trade port as shown in Appendix A. 
Com Err 
This  light  indicates  that  a  communication  error  occurred.  Use  the  LonWorks  Network 
Manager to troubleshoot the problem, or refer to Appendix B.1. 
RS-485  
(R1) 
These  lights  are  related  to  the  RS-485  serial  ports  provided  on  the  FieldServer.   The 
Rx (Receive) light will flash red if the FieldServer is receiving data.  The Tx (Transmit) 
light will flash red if the FieldServer is sending data.  (Note that due to the nature of 2-
wire RS-485 the Rx light will flash every time the Tx light flashes too). The frequency of 
the flashing is directly related to the frequency of data transfer. 
Ethernet 
Lights 
(N1,N2) 
These lights are related to the two Ethernet network ports provided on the FieldServer.  
The 10/100 light will be green if the physical connection to the network hub is running 
at  100  MBits/s.  If  the  light  is  off,  the  connection  is  running  at  10  MBits/s.  The  Act 
(Activity) light will indicate activity on the network.  The frequency of flashing is directly 
related to the network activity.  It does not necessarily mean data is being received by 
the FieldServer.  Note that Ethernet Port N2 supports 10 or 100 MBits/s, whereas N1 
only supports 10 MBits/s