43
Control and display elements
Global Error indicator (orange)
Lights up orange if a prefailure event has been detected that 
requires (precautionary) service intervention. 
Flashes orange if an error was detected that requires service 
intervention.
Does not light up if there is no critical event.
If the event is still acute after a power failure, the indicator is 
activated after the restart.
The indicator lights up in failure mode until the faults are cleared.
You can find more details on the indicated errors in the System 
Event Log (SEL), in the Management Blade Web interface, on the 
ServerView Local Service Panel, on the ServerView Local 
Service Display, in the ServerView Operations Manager or via the 
iRMC S2's Web interface.
CSS
CSS indicator (yellow)
Lights up yellow if a prefailure event was detected for a CSS 
component that you can fix yourself (for reasons of 
precaution) with the CSS concept.
Flashes yellow if an error was detected that you can fix 
yourself with the CSS concept.
Does not light up when the system is OK.
If the event is still acute after a power failure, the indicator is 
activated after the restart.
The indicator lights up in failure mode until the faults are cleared.
For more information on the CSS concept, se
.
ID
ID indicator (blue)
Lights up blue when the system has been selected by pressing the 
ID button. To deactivate, press the button again.
The ID indicator can also be activated via the Management Blade 
Web interface and via the ServerView Operations Manager and 
the iRMC S2 Web interface and its status reported to the 
ServerView Operations Manager and the iRMC S2.
!