Lucent Technologies 03.0.042.2 Benutzerhandbuch

Seite von 16
Change Descriptions
Release 8, Issue 3.0 (03.0.042.2)
8. Automatic Route Selection (ARS) calls were blocked (caller received 
reorder tone) when trunks were available but in a group controlled by the 
attendant.  Under these conditions, a denial event will be logged when an 
ARS call fails and at least one of the trunk groups in a preference is 
controlled by the attendant. 
9. It was possible to remove the administration for the TN802B or TN799B 
circuit packs even if an IP-interface was administered for that board. 
10. VuStats could display a "percent in service" value greater than 100 
percent. 
11. Calls transferred to a station that covered could cause a system reset. 
12. If a series of disconnects occurred in a very short time period, the Basic 
Rate Interface (BRI) trunk link state was put into a state that did not handle 
the hyperactive message from the packet interface board.  As a result, the 
link was taken out of service for about twenty minutes.  Now, the 
hyperactive state is handled and the link is taken out of service for about 
one minute.
13. Some calls to the attendant console could not be answered by the 
attendant, leaving the console locked up for several minutes until an audit 
cleared the condition.  Now, if a console is in a temporary state where a 
new call can’t be answered, all incoming calls are directed to another 
console until the condition clears. 
14. There were two display messages for which translations were not 
available.
15. If temporary bridged appearance for call pickup is set to "no" for the 
system, users were blocked from sending digits end-to-end using an 
auto-dial button, if the call was answered using a call pickup button. 
16. If IP-Softphone A was bridged to another Station B, and C called B, then A 
answered.  If another Station D called B and hung up after a ring, the call 
from C to A also dropped. 
17. A DEFINITY Wireless Business Systems (DWBS) user on a switch 
configured for Russian country-specific options did not get the Russian 
interdigit timeout.
18. It was impossible to invoke Automatic Callback (ACB) over a QSIG Basic 
Rate Interface (BRI) trunk after a “reset system 2”.  It was necessary to 
re-administer the maximum number of Non-Call Associated (NCA) 
Temporary Signaling Connections (TSCs) for the BRI trunk to get QSIG 
ACB working again.
19. The following statements:
1)
It was possible to list all administered IP SoftPhones using the “list 
multimedia ip-softphone” command.
2)
Access to the “list multimedia ip-softphone” command was blocked 
using the “mm-ip-softphone” keyword on the permissions form.