Lucent Technologies 555-233-115 Benutzerhandbuch
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Adding or Removing Cabinet Hardware
6-64
Add IP Interface Assembly
6
Administration Steps
1. Log in as craft.
2. Type change circuit-pack and press
Enter
.
3. Check the Code column to see if the slots above the TN802B say
DSMAPD or MEDPRO.
.
4. If MEDPRO, go to the entry just above the TN802B that says MEDPRO.
5. Type DSMAPD, and press
Enter
. Changing the one entry automatically
changes the entry above it. If it is in IP Trunk mode, you get the following
error message:
error message:
MedPro type requires TN802 with application. Type
MEDPRO on circuit-packs form.
Log onto the TN802B Interface Server
If administered remotely through pcANYWHERE:
1. Dial in to the server through pcANYWHERE using the dialup number
supplied.
2. Click on the pcANYWHERE Remote Host Computer button on the toolbar
to send
CTRL ALT DEL
to the host.
3. Type administrator in the
User Name
field.
4. Type iptrunk in the
Password
field and click OK.
5. After logging on for the first time, change the administrator password and,
if desired, the user name, to ensure security. See your Windows NT server
documentation for details.
documentation for details.
change circuit-packs Page 1 of 5
CIRCUIT PACKS
CIRCUIT PACKS
Cabinet: 1 Carrier: A
Carrier Type: processor
Carrier Type: processor
Slot Code Sf Mode Name Slot Code Sf Mode Name
11:
DSMAPD RESERVED-IP
01: TN754
DIGITAL LINE
12:
DSMAPD
RESERVED-IP
02: TN758
POOLED MODEM
13:
TN802 B
MAPD BOARD
03: TN2144
ANALOG LINE
14:
04: TN746 B
ANALOG LINE
15:
05
16:
06: TN771 C
MAINTENANCE/TEST
07: TN464 F
DS1 INTERFACE
08: TN2140
E&M TIE TRUNK
09: TN767 E
DS1 INTERFACE
10: TN799 B
CONTROL-LAN
’#’ indicates circuit pack conflict.