2-176   Operation, administration, and maintenance (OAM) features
OPTera Metro 3500 Multiservice Platform    NTRN10AN    Rel 12.1   Standard   Iss 1   Apr 2004
Two ways to manage VTs on a UPSR are:
Use dedicated STS at each node and provision STS connections at each 
pass-through VT-managed OPTera Metro 3000 node on the subtending 
UPSR
. This option is simple to implement and prevents VT traffic loss in 
case of a fiber cut. 
 shows a configuration that 
uses dedicated STS at each site and 
 shows the 
same configuration after a fiber cut. There is no loss of VT traffic.
Use a virtual ring with shared VT-managed STS. 
 shows a configuration that uses a virtual ring with shared 
VT-managed STS and 
 shows the same 
configuration after a fiber cut. There is no loss of VT traffic.
Note:  Using shared VT-managed STS can result in traffic loss in case of 
a fiber cut if the VTs are not managed correctly. For example, using an STS 
path selector on STS-managed OPTera Metro 3500 to terminate an STS 
which contains VTs from various nodes (a shared VT-managed STS) can 
result in VT traffic loss in case of a single fiber cut. See 
Figure 2-63
Per-site dedicated STS
EX1545p
OM3500
(W/VTX)
OM3500
(W/STX)
OM3500
(W/VTX)
OC-3/12/48
UPSR ring
Note:  For simplicity only one direction is shown.
OK
OK
VT#n, STS-1 #1
STS-1 #1
All VTs
STS-1 #2
All VTs
STS-1 #1
Path bridge & select
STS-1 #2
Path bridge & select
VT#n, STS-1 #2
OK
OK
Backbone
Network