Lucent Technologies lucent Benutzerhandbuch

Seite von 2392
DEFINITY Enterprise Communications Server  Release 6
Maintenance for R6vs/si  
555-230-127   
Issue 1
August 1997
Maintenance Commands and Trouble-Clearing Aids 
Page 8-266
status conference 
8
paths labeled CHL 1 and 2. For 2B calls, both CHL 1 and 2 are used. For 
1-channel calls (112,bps, 128kbps, 168kbps, 196kbps, 224kbps, 256kbps, 
280kbps, 320kbps, 336kbps, 384kbps, 768kbps, 1472kbps, 1536kbps, and 
1920kbps) only CHL 1 is used. 
A-OUT
A-IN
M-FRM
MFA
, and 
MFN
 are flags 
with 
y
 or 
n
.
Field descriptions
Page 4 - Endpoint Capability Information
This section describes fields specific to endpoint-level command output.
A-OUT
MCU has endpoint framing.
A-IN
Endpoint has MCU framing
M-FRM
Multichannel frame alignment of both channels in 2B is present.
MFA
Multiframe alignment word is present (required in 2B call).
MFN
Multiframe numbering is present (required in 2B call).
FAS
Frame Alignment Signal (FAS) channel number (1 or 2). This number 
should match the column header.
MCUFAL
MCU Frame Alignment Loss (MCUFAL). Counts the number of times 
the MCU reports lost endpoint FAW or multichannel synchronization 
(M-FRM) to the endpoint. The MCU a-bit toggles when the MCU gains 
or loses endpoint multichannel synchronization. This counter starts with 
0x00, increments to 0xff, then wraps around to 0x01. The MCUFAL 
count also displays in the 
Fr Err
 field on Page 2
FEFAL
Far End Frame Alignment Loss (FEFAL). Counts of the number of 
changes the MCU detects in the endpoint’s a-bit (A-OUT). The 
endpoint a-bit toggles when an endpoint gains or loses MCU framing. 
This counter starts with 0x00, increments to 0xff, then wraps around to 
0x01.