Polycom KIRK Wireless Server 8000 Installation Guide
1–2
General Installation Information
The maximum number of KWS 8000 units that can be linked together depends 
on the mounting method and the maximum length of the link cable: 
• Rack mount: 8 units
• Flat surface mount: 2 units
• Wall mount: 1 unit
General Mounting Safety Precautions
• Keep the area around the KWS8000 clean and free of clutter.
• Decide on a suitable location for the equipment rack that will hold the 
KWS8000 unit. It should be situated in a clean, dry, dust-free area that is 
well ventilated. Avoid areas where heat, electrical noise and 
electromagnetic fields are generated. 
• Place it near a grounded power outlet.
Installing the KWS8000 in a Rack
Before you start installation take notice of the following safety precautions.
Table 1-3
Power consumption
Power consumption
Typical AC Power Consumption
90 Watt
Max. AC Power Consumption
Max 360 Watt
Table 1-4
Environment
Environment
Operating temperature
0°C - 40°C (22° - 104°F)
Storage temperature
-30°C - 70°C (40° - 158°F)
Relative humidity
20% - 80% Non condensing
Operating altitude
Up to 2,000 m (6,500 ft)
Operating ESD level
4 KV