Hand Held Products IT4710 Benutzerhandbuch

Seite von 32
1 - 3
2D PQA Reporting
Full Report
HHP's 2D PQA reporting can be enabled in two different modes: Full Report or 
Screening.
If you are using Quick*View, you can enable Full Report, a listing of all of a sym-
bol's identifying information, measurements, and corresponding grades, by typ-
ing the following menu command:
 2D_PQA1
or by scanning the following bar code:
Note:  With the IT4600/4800/4X80, the PQA report is sent out as a second data/
beep sequence after the bar code data.  The report has its own HHP code 
ID of >(0X3E) so it can be uniquely identified.
Screening Report
Screening is a grade-based mode that allows display of a limited list of identify-
ing information, as well as only those measurements that are below Minimum 
Acceptable Grade (MAG) level.  With the IT4600/4800/4X80, if all of the param-
eters are met in the screening mode, only the bar code data will be output with a 
beep.  If one or more of the measured parameters fail to meet the MAG, the 
PQA message is also sent with a beep.
Note:  With the IT4410/4710, screening mode outputs are also accompanied by 
a single beep if all parameters are okay or a triple beep if one or more of 
the measured parameters fail to meet the MAG.
If you are using Quick*View, you can enable Screening by typing the following 
menu commands:
 2D_PQA2
when A is the Minimum Acceptable Grade
 2D_PQA3
when B is the Minimum Acceptable Grade
 2D_PQA4
when C is the Minimum Acceptable Grade
 2D_PQA5
when D is the Minimum Acceptable Grade
Full Report