Writing parameters to ROM is also possible with commands via RS-232C. 
When writing parameters to ROM, a reply that definitely contains data will be sent by a controller. 
The content of data is different by a parameter.    (For details, see 9.2.    “Parameter Details”) 
(Note: Carry out writing parameters to ROM only after thoroughly verifying the content. Depending on 
the changed values, the controller may not start normally.)
 
 
    Parameter ROM Write send 
     
E        Axis No.        P    Parameter ID        /        Data          Delimiter 
 
 
 
 
 
 
 
          E.g.  LQ gain parameter  ID = 6    Data = 4500 
           E1P006 / 4500 (LF) 
                            (ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x34 0x35 0x30 0x30 0x0a) 
                                                      E        1        P      0        0        6        /      4          5        0      0      (LF) 
 
 
   Parameter ROM Write reply 
     
E        Axis No.        P    Parameter ID        /        Data          Delimiter 
 
 
 
 
 
 
 
          E.g.  LQ gain parameter  ID = 6    Data = 4500 
           E1P006 / 4500 (LF) 
                            (ASCII code: 0x45 0x31 0x50 0x30 0x30 0x36 0x2f 0x30 0x0a) 
                                                      E        1        P      0        0        6        /        0      (LF) 
 
 
 
Axis No. 
1 or 2 
Parameter ID 
Decimal, 3-digit 
(See 7.1 for details)
Parameter setting 
Decimal 
Parameter 
Delimiter
LF or CR 
Axis No. 
1 or 2 
Parameter ID 
Decimal, 3-digit 
(See 7.1 for details)
Parameter setting 
successful / unsuccessful 
0 or 1 
Parameter 
Delimiter
LF or CR