Opticon CRD972X Benutzerhandbuch

Seite von 23
16 - OPTICON   OPL972X/CRD972X
2.3.5 CONNECT RS485 MULTICRADLE 
NETWORK 
THIS PART DESCRIBES THE NETWORK 
DETAILS. FOR CONNECTION DETAILS REFER 
TO PREVIOUS PAGE.
TAKE NOTICE OF THE NECESSARY 
PRECAUTIONS THAT NEEDS BE MADE TO 
ESTABLISH A PROPER NETWORK 
CONNECTION AS DESCRIBED BELOW.
Connect RS232
Only 1 multicradle in the network will be connected 
to the PC through one RS232 cable. For RS232 
interface use the left RS232 connector (RS232C-
1). Through this connection all multicradles can 
communicate to the PC.
Connect RS485
A maximum of 16 multicradles can be connected in 
a network through RS485 cables.
Set DIP switch settings
For (default) settings notice DIP switch table in the 
next chapter.
• All multicradles in the network need to be set to 
RS232/RS485 connection.
• All multicradles need to have the same baud rate 
to be set by DIP switch.
• The first and the last multicradle in the network 
must have the termination resistors set.
LED indicator
Typical LED indications are:
red: power is on
flashing green: collector sends to host
flashing yellow: host sends to collector
MASTER
RS232/RS485 
TERMINATE
SLAVE
RS232/RS485 
SLAVE
RS232/RS485 
TERMINATE
ON
1    2    3    4    5    6